24 db
-
TP-Link Switch PoE – TL-SL1226P (24port 100Mbps, 24 af PoE port, 2x Combo SFP, 250W, 250m extended mode)
131 800 FtHARDWARE FEATURES
Interface
24× PoE+ 10/100 Mbps RJ45 Ports
2× 10/100/1000 Mbps RJ45 Ports
2× Combo Gigabit SFP Slots
Network Media
10BASE-T: UTP category 3, 4, 5 cable (maximum 100m)
EIA/TIA-568 100Ω STP (maximum 100m)
100BASE-TX: UTP category 5, 5e cable (maximum 100m)
EIA/TIA-568 100Ω STP (maximum 100m)
1000BASE-T: UTP category 5, 5e, 6 or above cable (maximum 100m)
EIA/TIA-568 100Ω STP (maximum 100m)
1000BASE-X MMF, SMF
Fan Quantity 2 Fans
Physical Security Lock Yes
Power Supply 100-240 VAC, 50/60 Hz
Backup Bandwidth 8.8 Gbps
PoE+ Ports(RJ45)
Standard: 802.3at/802.3af compliant
PoE Ports: Port 1 – Port 24
PoE Power Budget: 250 W
Mac Address Table 8 K
Dimensions ( W x D x H ) 17.3 × 7.1 × 1.7 in (440 × 180 × 44 mm)
Max Power Consumption 18.32 W (220/50 Hz. no PD connected)
294 W (220/50 Hz. with 250 W PD connected)
Max Heat Dissipation 62.47 BTU/h (no PD connected)
1002.54 BTU/h (with 250 W PD connected)
SOFTWARE FEATURES
Advanced Features
Compatible With IEEE 802.3at/af Compliant PDs
Extend Mode (Up to 250m PoE power supply and data transmission)
Priority Mode
Isolation Mode
PD Detection
Intelligent Power Supply
Mac Address Auto-Learning and Auto-Aging
IEEE802.3x Flow Control
Transmission Method Store-And-Forward
OTHERS
Certification CE, FCC, RoHS
Package Contents
TL-SL1226P
Power Cable
Installation Guide
Two mounting brackets and the fittings
Environment
Operating Temperature: 0–50 °C (32–122 °F)
Storage Temperature: -40–70 °C (-40–158 °F)
Operating Humidity: 10–90% non-condensing
Storage Humidity: 5–90% non-condensing -
TP-Link Switch Easy Smart PoE – TL-SG1428PE JetStream™ (26 port 1Gbps, 24x af/at PoE+ port, 2x SFP port, 250W)
132 600 FtHARDWARE FEATURES
Standards and Protocols IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x
IEEE 802.3af, IEEE 802.3at, IEEE 802.1q, IEEE 802.1p
Interface 26 10/100/1000 Mbps RJ45 Ports
2 Gigabit SFP Ports
Network Media 10BASE-T: UTP category 3, 4, 5 cable (maximum 100m)
EIA/TIA-568 100Ω STP (maximum 100m)
100BASE-TX: UTP category 5, 5e cable (maximum 100m)
EIA/TIA-568 100Ω STP (maximum 100m)
1000BASE-T: UTP category 5, 5e, 6 or above cable (maximum 100m)
EIA/TIA-568 100Ω STP (maximum 100m)
1000BASE-X MMF, SMF
Fan Quantity 2 Fans
Physical Security Lock Yes
Power Supply 100-240V AC, 50/60 Hz
PoE+ Ports(RJ45) Standard: 802.3at/802.3af compliant
PoE+ Ports: 24 Ports
Power Supply: 250 W
Dimensions ( W x D x H ) 17.3 × 8.7 × 1.73 in (440 × 220 × 44 mm)
Mounting Rack Mountable
Max Power Consumption 27 W (220/50Hz. no PD connected)
304.7 W (220/50Hz. with 250 W PD connected)
Max Heat Dissipation 92.07 BTU/h (no PD connected)
1039.03 BTU/h (with 250 W PD connected)
PERFORMANCE
Switching Capacity 56 Gbps
Packet Forwarding Rate 41.7 Mbps
MAC Address Table 8K
Packet Buffer Memory 4.1 Mbit
Jumbo Frame 9 KB
SOFTWARE FEATURES
Quality of Service Support Port-based 802.1p/DSCP priority
Support 4 priority queues
Rate Limit
Storm Control
L2 Features IGMP Snooping V1/V2/V3
Static Link Aggregation
Port Mirroring
Cable Diagnostics
Loop Prevention
PoE Auto Recovery
VLAN Support up to 32 VLANs simultaneously (out of 4K VLAN IDs)
MTU/Port/Tag VLAN
Management Web-Based GUI
Easy Smart Configuration Utility
Transmission Method Store-And-Forward
OTHERS
Certification CE, FCC, RoHS
Package Contents TL-SG1428PE
Power Cord
Installation Guide
Rackmount Kit
Rubber Feet
Environment Operating Temperature: 0°C~50°C (32°F~122°F)
Storage Temperature: -40°C~70°C (-40°F~158°F)
Operating Humidity: 10% ~ 90% non-condensing
Storage Humidity: 5%~90% non-condensing -
TP-Link Switch Smart PoE – TL-SG2428P JetStream™ (L2,L2+, IPv6, 24port 1Gbps + 4port SFP, 24 af/at PoE+ port, 250W)
178 100 FtHardver jellemzők
Szabványok és protokollok IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE802.3z, IEEE 802.3ad, IEEE 802.3x, IEEE 802.3az, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1q, IEEE 802.1p, IEEE 802.1x
Csatlakozások
• 24× 10/100/1000 Mbps RJ45 Ports (Auto Negotiation/Auto MDI/MDIX)
• 4× Gigabit SFP Slots
Hálózati összeköttetés
• 10BASE-T: UTP category 3, 4, 5 cable (maximum 100m)
• 100BASE-TX/1000Base-T: UTP category 5, 5e or above cable (maximum 100m)
• 1000BASE-X: MMF, SMF
Ventilátorok száma 2
PoE+ portok (RJ45)
• Standard: 802.3at/af compliant
• PoE+ Ports: 24 Ports
• Power Supply: 250 W
Méretek (Sz x Mé x Ma) 17.3 × 8.7 × 1.73 in (440 × 220 × 44 mm)
Felszerelés Rack Mountable
Max. áramfelvétel
• 32.1 W (110 V/ 60 Hz with no PD connected)
• 308.6 W (110 V/ 60 Hz with 250 W PD connected)
Max Heat Dissipation
• 109.53 BTU/h (with no PD connected)
• 1052.94 BTU/h (with 250 W PD connected)
Működési jellemzők
Sávszélesség/Backplane 56 Gbps
Csomagtovábbítási sebesség 41.7 Mpps
Fizikai (MAC) cím tábla 8K
Csomag puffer memória 4.1 Mbit
Jumbo Frame 9KB
Szoftver jellemzők
QoS (szolgáltatás minősége)
• Support 802.1p CoS/DSCP priority
• Support 8 priority queues
• Queue scheduling: SP, WRR, SP+WRR
• Port/Flow- based Rate Limiting
• IPv6 QoS
• Voice VLAN
L2 és L2+ jellemzők
• Static Routing
• DHCP Relay
• DHCP Server
• IGMP Snooping V1/V2/V3
• 802.3ad LACP (Up to 8 aggregation groups, containing 8 ports per group)
• Spanning Tree STP/RSTP/MSTP
• BPDU Filtering/Guard
• TC/Root Protect
• Loopback detection
• 802.3x Flow Control
• LLDP, LLDP-MED
VLAN
• Supports up to 4K VLANs simultaneously (out of 4K VLAN IDs)
• MAC/Protocol-based VLAN
Hozzáférés-jogosultsági lista (ACL)
• L2–L4 package filtering
• MAC ACL
• IP ACL
• Combined ACL
• IPv6 ACL
Biztonság
• AAA
• Port Security
• DHCP Snooping
• IP-MAC-Port Binding
• IPv6-MAC-Port Binding
• ARP Inspection
• 802.1x and Radius Authentication
• SSH v1/v2
• SSL v3/TLSv1.2
• Broadcast/Multicast/Unknown-unicast Storm Control
• Dos Defend
IPv6
• Dual IPv4/IPv6 stack
• Multicast Listener Discovery (MLD) Snooping
• IPv6 neighbor discovery (ND)
• Path maximum transmission unit (MTU) discovery
• Internet Control Message Protocol (ICMP) version 6
• TCPv6/UDPv6
IPv6 alkalmazás
• DHCPv6 Client
• Ping6
• Tracert6
• Telnet (v6)
• IPv6 SNMP
• IPv6 SSH
• IPv6 SSL
• Http/Https
• IPv6 TFTP
Vezérlés
Omada App Yes
Centralized Management
• Omada Cloud-Based Controller
• Omada Hardware Controller (OC300)
• Omada Hardware Controller (OC200)
• Omada Software Controller
Cloud Access Yes (Through OC300, OC200, Omada Cloud-Based Controller, or Omada Software Controller)
Management Features
• Web-based GUI and CLI management
• SNMP v1/v2c/v3,compatible with public MIBs and TP-Link private MIBs
• RMON (1, 2, 3, 9 groups)
• CPU Monitoring
• Port Mirroring
• Firmware Upgrade: TFTP & Web
• System Diagnose: VCT
• SYSLOG & Public MIBS
• Dual Image
• EEE
Egyéb jellemzők
Tanúsítványok CE, FCC, RoHS
Csomagolás tartalma TL-SG2428P
• Power Cord
• Installation Guide
• Rackmount Kit
• Rubber Feet
Rendszerkövetelmény Microsoft® Windows® XP, Vista™ or Windows 7, Windows 8, Windows 10, MAC® OS, NetWare®, UNIX® or Linux.
Környezet
• Operating Temperature: 0–40 ? (32–104 ?);
• Storage Temperature: -40–70 ? (-40–158 ?)
• Operating Humidity: 10–90% RH non-condensing
• Storage Humidity: 5–90% RH non-condensing -
TP-Link Switch Smart – TL-SG3428XMP JetStream™ (24 port 1Gbps PoE+ port, 4 port 10Gbps SFP, 384W, L2/L3/L4)
317 200 FtHARDWARE FEATURES
Interface
• 24× 10/100/1000 Mbps RJ45 Ports
• 4× 10G SFP+ Slots
• 1× RJ45 Console Port
• 1× Micro-USB Console Port
Fan Quantity 2
Power Supply 100-240 V AC~50/60 Hz
PoE+ Ports(RJ45)
• Standard: 802.3at/af compliant
• PoE+ Ports: 24 Ports, up to 30 W per port
• Power Budget: 384 W
Dimensions ( W x D x H ) 17.3 × 13.0 × 1.7 in (440 × 330 × 44 mm)
Mounting Rack Mountable
Max Power Consumption
34.4 W (110V/60Hz) ( no PD device connected)
465.8 W (110V/60Hz) ( with 384 W PD device connected)
Max Heat Dissipation
117.38 BTU/h (110 V/60 Hz) (no PD device connected)
1589.31 BTU/h (110 V/60 Hz) (with 384 W PD device connected)
PERFORMANCE
Switching Capacity 128 Gbps
Packet Forwarding Rate 95.23 Mpps
MAC Address Table 16 K
Jumbo Frame 9 KB
SOFTWARE FEATURES
Quality of Service
• 8 priority queues
• 802.1p CoS/DSCP priority
• Queue scheduling
– SP (Strict Priority)
– WRR (Weighted Round Robin)
– SP+WRR
• Bandwidth Control
– Port/Flow based Rating Limiting
• Smoother Performance
• Action for Flows
– Mirror (to supported interface)
– Redirect (to supported interface)
– Rate Limit
– QoS Remark
L2 and L2+ Features
• Link Aggregation
– static link aggregation
– 802.3ad LACP
– Up to 8 aggregation groups, containing 8 ports per group
• Spanning Tree Protocol
– 802.1d STP
– 802.1w RSTP
– 802.1s MSTP
– STP Security: TC Protect, BPDU Filter, Root Protect
• Loopback Detection
– Port based
– VLAN based
• Flow Control
– 802.3x Flow Control
– HOL Blocking Prevention
• Mirroring
– Port Mirroring
– CPU Mirroring
– One-to-One
– Many-to-One
– Tx/Rx/Both
L2 Multicast
• IGMP Snooping
– IGMP v1/v2/v3 Snooping
– Fast Leave
– IGMP Snooping Querier
– IGMP Authentication
• IGMP Authentication
• MLD Snooping
– MLD v1/v2 Snooping
– Fast Leave
– MLD Snooping Querier
– Static Group Config
– Limited IP Multicast
• MVR
• Multicast Filtering: 256 profiles and 16 entries per profile
VLAN
• VLAN Group
– Max 4K VLAN Groups
• 802.1Q Tagged VLAN
• MAC VLAN: 7 Entries
• Protocol VLAN: Protocol Template 16, Protocol VLAN 16
• Private VLAN
• GVRP
• VLAN VPN (QinQ)
– Port-Based QinQ
– Selective QinQ
• Voice VLAN
Access Control List
• Time-based ACL
• MAC ACL
– Source MAC
– Destination MAC
– VLAN ID
– User Priority
– Ether Type
• IP ACL
-Source IP
– Destination IP
– Fragment
– IP Protocol
– TCP Flag
– TCP/UDP Port
– DSCP/IP TOS
– User Priority
• Combined ACL
• Packet Content ACL
• IPv6 ACL
• Policy
– Mirroring
– Redirect
– Rate Limit
– QoS Remark
• ACL apply to Port/VLAN
Security
• IP-MAC-Port Binding
– 512 Entries
– DHCP Snooping
– ARP Inspection
– IPv4 Source Guard: 100 Entries
• IPv6-MAC-Port Binding
– 512 Entries
– DHCPv6 Snooping
– ND Detection
– IPv6 Source Guard: 100 Entries
• DoS Defend
• Static/Dynamic Port Security
– Up to 64 MAC addresses per port
• Broadcast/Multicast/Unicast Storm Control
– kbps/ratio control mode
• 802.1X
– Port base authentication
– Mac base authentication
– VLAN Assignment
– MAB
– Guest VLAN
– Support Radius authentication andaccountability
• AAA (including TACACS+)
• Port Isolation
• Secure web management through HTTPS with SSLv3/TLS 1.2
• Secure Command Line Interface (CLI) management with SSHv1/SSHv2
• IP/Port/MAC based access control
IPv6
• IPv6 Dual IPv4/IPv6
• Multicast Listener Discovery (MLD) Snooping
• IPv6 ACL
• IPv6 Interface
• Static IPv6 Routing
• IPv6 neighbor discovery (ND)
• Path maximum transmission unit (MTU) discovery
• Internet Control Message Protocol (ICMP) version 6
• TCPv6/UDPv6
• IPv6 applications
– DHCPv6 Client
– Ping6
– Tracert6
– Telnet (v6)
– IPv6 SNMP
– IPv6 SSH
– IPv6 SSL
– Http/Https
– IPv6 TFTP
L3 Features
• 16 IPv4/IPv6 Interfaces
• Static Routing
– 48 static routes
• Static ARP
– 128 Static Entries
• Proxy ARP
• Gratuitous ARP
• DHCP Server
• DHCP Relay
– DHCP Interface Relay
– DHCP VLAN Relay
• DHCP L2 Relay
Management
• Web-based GUI
• Command Line Interface (CLI) through the console port, telnet
• SNMP v1/v2c/v3
– Trap/Inform
– RMON (1,2,3,9 groups)
• SDM Template
• DHCP/BOOTP Client
• 802.1ab LLDP/LLDP-MED
• DHCP AutoInstall
• Dual Image, Dual Configuration
• CPU Monitoring
• Cable Diagnostics
• EEE
• Password Recovery
• SNTP
• System Log
Advanced Features
• Support Omada Hardware Controller (OC200/OC300), Software Controller, Cloud-Based Controller
• Automatic Device Discovery
• Batch Configuration
• Batch Firmware Upgrading
• Intelligent Network Monitoring
• Abnormal Event Warnings
• Unified Configuration
• Reboot Schedule
• ZTP (Zero-Touch Provisioning)**
MIBs • MIB II (RFC1213)
• Interface MIB (RFC2233)
• Ethernet Interface MIB (RFC1643)
• Bridge MIB (RFC1493)
• P/Q-Bridge MIB (RFC2674)
• RMON MIB (RFC2819)
• RMON2 MIB (RFC2021)
• Radius Accounting Client MIB (RFC2620)
• Radius Authentication Client MIB (RFC2618)
• Remote Ping, Traceroute MIB (RFC2925)
• Support TP-Link private MIB
OTHERS
Certification CE, FCC, RoHS
Package Contents
• TL-SG3428XMP Switch
• Power Cord
• Quick Installation Guide
• Rackmount Kit
• Rubber Feet
Environment
• Operating Temperature: 0–45 ? (32–113 ?);
• Storage Temperature: -40–70 ? (-40–158 ?)
• Operating Humidity: 10–90% RH non-condensing
• Storage Humidity: 5–90% RH non-condensing